XH-W1088 220Vac Dual Digital Programmable Temperature Controller 10A

https://www.ram-electronics.com/web/image/product.template/8279/image_1920?unique=9b97f50

Thermostat Control Switch Probe -50°C ~ 120°

550.00 EGP 550.0 EGP 550.00 EGP

550.00 EGP

Not Available For Sale

This combination does not exist.

 Pick up from RAM Store
 Shipping: 2-3 Business Days


Internal Reference: XH.W1088.220V.1500W

XK-W1088 AC 220V Dual Digital Thermostat Temperature Controller 2 Relay Output with dual Dual Probe for incubator Features:

  • Heating or cooling control
  • Red and blue dual-LED display
  • Independent Dual-way temperature controller
  • Temperature display resolution 0.1
  • Directly power output
  • Support high (low) temperature alarms and support for power loss
  • The application range is like home temperature control, farm, various cold storage, greenhouse, aquarium, etc

Specifications:

  • Display Type: Digital
  • Material: ABS+PCB
  • Style: Standing Station
  • Temperature sensor: NTC 10K
  • Sensor length: 1.0m
  • Temperature measuring range: -55 °C ~ 120°C
  • Resolution: 0.1°C
  • Accuracy: ±1°C
  • Power supply: 110-220VAC 50/60Hz
  • Power consumption: <3W
  • Storage temperature: -30°C ~ 75 °C
  • Relative humidity: 20% ~ 85% (No condensate)
  • Relay contact capacity: Two Relay Max 10A, Direct Output
  • Item Size: 7.5*5.5*3.1 cm
  • Item Weight: 80g

Set startup temperature: 

Press the "up" button once to display the starting temperature. Long press the "up" button for about 3 seconds, The required temperature can be set by the up and down keys 

Set the stop temperature: 

Press the button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the up and down keys Press "Up 1" Button & "Up 2"Button at the same time to setting mode 

How to restore factory Settings 

Press the "Down 1" and "Down 2" button at the same time, the factory setting is restored 

Temperature correction 

Press “Up 1 ”and “Down 1 ”at the same times for 3 seconds. positive value = measured value + corrected value(group 2 temperature correction is the same method ) 

Note: 

Heating Mode - Start temperature < Stop temperature Cooling Mode -- Start temperature> Stop temperature 

Code P0 Function Compressor 1 delay time Set Range 0-60min Default 0min 

Code P1 Function Compressor 2 delay time Set Range 0-60min Default 0min 

Code P2 Function High-temperature alarm value Set Range -55~120°C/-67~248°F Default 120°C/248°F 

Code P3 Function Low-temperature alarm value Set Range -55~120°C/-67~248°F Default -55°C/-67°F