FNIRSI® SG-002 Signal Generator & Calibrator 4-20mA ±12V (Current & Voltage Generator)

https://www.ram-e-shop.com/web/image/product.template/9645/image_1920?unique=1497655 KIT.SIGNAL.GEN.SG002

With PLC Analog Input Testing Function

1,250.00 EGP 1250.0 EGP 1,250.00 EGP

1,250.00 EGP

Not Available For Sale

This combination does not exist.

1 Year Warranty

 Pick up from RAM Store
 Shipping: 2-3 Business Days


Internal Reference: KIT.SIGNAL.GEN.SG002

FNIRSI® ±12V/0-24mA Voltage and Current Source Signal Generator

Product Description

The FNIRSI® ±12V / 0~24mA Voltage and Current Source Signal Generator is a compact adjustable signal source designed for testing, calibration, and troubleshooting industrial control systems and electronic equipment. It provides adjustable DC voltage output from -12V to +12V and current output from 0 to 24mA, making it suitable for testing analog input channels, PLCs, inverters, controllers, and other industrial automation equipment.

The device features a four-digit digital display with two decimal places, allowing users to monitor the selected output value. A rotary encoder provides convenient adjustment, while the MODE button allows quick switching between voltage and current output modes.

The voltage output supports multiple configurable ranges, including ±12V, ±5V, 0–10V, 2–10V, 0–5V, 1–5V, 0–3.3V, 0–2.5V, 0–1V, and -10–0V. The current output supports 0–20mA, 4–20mA, and 0–24mA modes.

The generator also provides adjustable coarse and fine output control, output calibration settings, and programmable quick-output points. Users can save the current output value so that the device restores the saved value after the next startup.

For flexible operation, the unit supports three power supply methods: an external DC power supply, a USB 5V input, and an optional built-in rechargeable lithium battery. Its compact enclosure and terminal-based connections make it suitable for field testing and industrial maintenance work.

Key Features

  • Dual Voltage and Current Output: Provides adjustable voltage and current signals for testing industrial equipment.
  • Adjustable Voltage Output: Supports output adjustment from -12V to +12V.
  • Adjustable Current Output: Supports output adjustment from 0 to 24mA.
  • Multiple Voltage Ranges: Configurable output modes include ±12V, ±5V, 0–10V, 2–10V, 0–5V, 1–5V, 0–3.3V, 0–2.5V, 0–1V, and -10–0V.
  • Multiple Current Ranges: Supports 0–20mA, 4–20mA, and 0–24mA output modes.
  • Four-Digit Digital Display: Displays output values with two decimal places.
  • Rotary Encoder Control: Allows convenient adjustment of voltage and current output values.
  • One-Button Mode Switching: Switches between voltage and current adjustment modes using the MODE button.
  • Coarse and Fine Adjustment: Provides selectable adjustment modes for faster or more precise output setting.
  • Output Calibration: Supports calibration settings at multiple reference points for voltage and current output.
  • Quick Output Function: Supports programmable output points for convenient switching between predefined values.
  • Output Value Memory: Saves the selected output value for restoration after the next startup.
  • Multiple Power Supply Options: Supports external DC power, USB 5V power, and an optional internal rechargeable battery.
  • Active and Passive Current Wiring: Supports different current-loop connection configurations, as illustrated in the wiring diagrams in the manual.
  • Compact Design: Suitable for industrial maintenance, equipment commissioning, and field testing.

Technical Specifications

General Specifications

ParameterSpecification
Product TypeVoltage and Current Source Signal Generator
Voltage Output Range±12V
Current Output Range0–24mA
Display4-Digit Digital Display
Display Resolution FormatTwo Decimal Places
Adjustment ControlRotary Encoder
Mode SelectionMODE Button
DimensionsApproximately 70 × 90 × 27mm
Encoder Resolution30 Pulses per Revolution

Voltage Output Specifications

ParameterSpecification
Adjustable Output Range-12V to +12V
Accuracy After Calibration0.05V
Maximum Output Current20mA
Available Output Modes±12V, ±5V, 0–10V, 2–10V, 0–5V, 1–5V, 0–3.3V, 0–2.5V, 0–1V, -10–0V
Coarse AdjustmentAdjustable
Fine AdjustmentAdjustable
Calibration Reference Points-10V, 0V, +10V

Current Output Specifications

ParameterSpecification
Adjustable Output Range0–24mA
Accuracy After Calibration0.05mA
Maximum Sampling Resistance500Ω
Available Output Modes0–20mA, 4–20mA, 0–24mA
Coarse AdjustmentAdjustable
Fine AdjustmentAdjustable
Calibration Reference Points4mA, 12mA, 20mA

Power Supply Specifications

ParameterSpecification
External DC Power Supply15–30V DC
External DC Power Consumption1W (not charging) / 4W (charging)
USB InputMicro-USB 5V
USB Current Consumption0.2A (not charging) / 0.8A (charging)
Internal Battery3.7V Lithium Battery
Battery Capacity1100mAh (optional)
Maximum Battery Charging Current0.6A

Additional Configuration Settings

ParameterDescription
Coarse/Fine AdjustmentSelectable
Output DisplayActual value or percentage, depending on mode
Digital Display Brightness8 levels
Quick Output Points2–9 programmable points
Output Value StorageSupported
Automatic Exit from SettingsAfter 10 seconds without operation

Applications

  • PLC Analog Input Testing: Generate adjustable voltage and current signals for checking PLC analog input channels.
  • Industrial Automation: Test analog signal inputs in industrial controllers and automation systems.
  • Inverter and Servo System Testing: Provide adjustable signals for checking compatible inverter and servo control interfaces.
  • 4–20mA Current Loop Testing: Generate current signals for testing industrial transmitters, controllers, and analog input circuits.
  • 0–10V Signal Testing: Test voltage-based analog control inputs and signal-processing circuits.
  • Instrumentation Calibration: Provide adjustable reference signals for checking and calibrating compatible industrial instruments.
  • Control System Troubleshooting: Help identify signal-related problems in industrial equipment and control circuits.
  • Equipment Commissioning: Test analog input channels during installation, setup, and maintenance.

Frequently Asked Questions (FAQ)

1. What output signals does the FNIRSI Voltage and Current Source Signal Generator provide?

It provides adjustable DC voltage output from -12V to +12V and current output from 0 to 24mA. It can be used to generate signals for testing compatible industrial control equipment.

2. Does the device support standard 4–20mA current signals?

Yes. The current output can be configured to 0–20mA, 4–20mA, or 0–24mA, making it suitable for testing compatible 4–20mA industrial current-loop systems.

3. What voltage output ranges are supported?

The available voltage modes include ±12V, ±5V, 0–10V, 2–10V, 0–5V, 1–5V, 0–3.3V, 0–2.5V, 0–1V, and -10–0V.

4. Can I adjust the output signal precisely?

Yes. The device provides coarse and fine adjustment modes through its rotary encoder. The specified accuracy after calibration is 0.05V for voltage output and 0.05mA for current output.

5. Can the generator be used to test PLC analog input channels?

Yes. It can generate adjustable voltage and current signals for testing compatible PLC analog input channels. The wiring configuration must match the PLC input type and the manufacturer's connection diagram.

6. What is the difference between active and passive current-loop connections?

Active and passive connections refer to different current-loop wiring arrangements. The manual provides wiring diagrams for active and passive current connections, including 2-, 3-, and 4-wire configurations. Always check the PLC or controller input wiring requirements before connecting the generator.

7. How can I power the signal generator?

The device supports three power supply methods: an external 15–30V DC power supply, a 5V Micro-USB input, or an optional internal 3.7V 1100mAh rechargeable lithium battery.

8. Does the device remember the last output value?

Yes. A short press of the encoder confirmation button saves the current output value. After the next startup, the device restores the saved value. This is useful when repeatedly testing equipment at the same signal level.

Download