Original LG Battery Lithium Li-Ion LG INR18650MH1 (LG MH1) 3200mAh 10A 4.2/3.7/2.5V Rechargeable
Internal Reference:
BATTERY.18650.LG
- Original industrial (unprotected) cylindrical Li-Ion battery.
- Size: 18650
- Manufacturer: LG
Nominal Specification
-
Capacity:
By standard charge/discharge
Nominal: 3200mAh
Minimum: 3100mAh -
Nominal Voltage:
Average by standard charge/discharge: 3.70V -
Shipping Cell Voltage:
At ex-factory state: Approximately SOC 30% - Standard Charge:
- Constant current (1C = 3100mA): 0.5C (1,550mA)
- Constant voltage: 4.20V
- End condition (Cut off): 50mA
- Charging time: 3 hours
- Max. Charge Voltage:
In all measurements and operations of the cell, the maximum allowable closed circuit voltage shall not exceed 4.20V -
Max. Charge Current (complete full charge):
Atmosphere temperature: 0 ~ 50℃
Maximum current: 1.0C (3,100mA) - Standard Discharge:
- Constant current: 0.2C (620mA)
- End voltage (Cut off): 2.50V
- Min. Discharge Voltage:
In all measurements and operations of the cell, the minimum allowable closed circuit voltage shall not be below 2.50V - Max. Discharge Current:
- Temperature -20 ~ 0℃: 0.5C (1,550mA) (10A peak current under 10 sec)
- Temperature 0 ~ 10℃: 6.0A (6,000mA) (10A peak current under 10 sec)
- Temperature 10 ~ 60℃: 10A (10,000mA)
- Over Voltage Protection:
Cell voltage shall not exceed 4.25V to prevent any safety events.
Cell performance can't be guaranteed between 4.20V and 4.25V. -
Under Voltage Protection:
Cell voltage shall not drop below 2.00V to prevent any safety events.
Cell performance can't be guaranteed between 2.50V and 2.00V. -
Weight:
Tubing cell: 44.5 ± 1.0g - Operating Temperature (Atmosphere or Chamber Temperature):
- Charge: 0 ~ 50℃
-
Discharge: -20 ~ 60℃
(* Max. cell surface temperature should be below 70℃ for discharging. Temperature cut-off function is needed on BMU under 70℃ of cell surface temperature.)
-
Discharge: -20 ~ 60℃
- Storage Temperature (for shipping state):
- 1 month: -20 ~ 60℃
- 3 months: -20 ~ 45℃
-
1 year: -20 ~ 25℃
Recovery capacity after the storage ≥ 80% of minimum energy (or capacity)
-
1 year: -20 ~ 25℃
- Storage Temperature (for fully charged state):
- 1 month: -20 ~ 45℃
-
3 months: -20 ~ 25℃
Recovery capacity after the storage ≥ 80% of minimum energy (or capacity)
-
3 months: -20 ~ 25℃
- Storage Humidity:
25–50%