W3230 Panel Type Programmable Temperature Control Switch Relay

https://www.ram-e-shop.com/web/image/product.template/9241/image_1920?unique=166a5f8

Thermostat Switch

7.88 7.875 USD 7.88

375.00 EGP

Not Available For Sale

هذه التركيبة غير موجودة.

 متاح للشراء مباشرة من فرع رام للالكترونيات
 متاح خدمة الشحن للمنتج خلال 2-3 ايام عمل


مرجع داخلي: KIT.W3230.TEMP.CONTROL

W3230 DC12V Digital Temperature Controller – Microcomputer Thermostat Switch with 1m Sensor Cable

Specifications:

  • Model: W3230
  • Power Supply: DC 12V
  • Temperature Control Range: -50°C to 120°C
  • Resolution: 0.1°C (-9.9 to 99.9°C), 1°C for other ranges
  • Measurement Accuracy: ±0.1°C
  • Control Accuracy: ±0.1°C
  • Display: Dual LED display – Red for actual temperature, Blue for set temperature
  • Sensor Type: NTC 10K waterproof probe, 1m cable length
  • Relay Output Capacity: 20A @ 12V DC / 10A @ 220V AC
  • Operating Temperature: -10°C to 60°C
  • Operating Humidity: 20% to 85% RH
  • Dimensions: 79 × 43 × 26 mm
  • Panel Cutout Size: 73 × 39 mm
  • Weight: Approx. 44g

Functions & Features:

  • Selectable Heating or Cooling mode
  • Adjustable temperature hysteresis (0.1°C to 15°C)
  • Upper and lower temperature limits setting
  • Temperature calibration function (-7°C to +7°C)
  • Delay start function (0–10 minutes)
  • Data storage to retain settings after power loss
  • Factory reset option
Programming:
1. Function Overview
  • P0 – Select Mode: Refrigeration (C) or Heating (H)
  • P1 – Return Difference (Hysteresis) Setting
  • P2 – Maximum Temperature Limit
  • P3 – Minimum Temperature Limit
  • P4 – Temperature Calibration (Correction)
  • P5 – Delay Start Time (minutes)
  • P7 – Memory Function (Save Settings after Power Loss)
2. Quick Start
  1. Set Target Temperature
    • Press SET once → temperature display flashes.
    • Press + / – to adjust target temperature (hold for fast change).
    • Press SET to confirm.
    • The controller will automatically switch the relay ON/OFF according to the set temperature.
  2. Power & Output
    • Relay Output: 10A – suitable for high-power loads.
    • Display shows the current ambient temperature during normal operation.
3. Display & Indicators
  • Indicator Light
    • Flashing = Delay start is active.
    • Solid ON = Relay is energized (output ON).
  • Display Messages
    • LL = Sensor not connected.
    • HH = Temperature out of range – relay forced OFF.
    • – – – = High temperature alarm.
4. Parameter Settings

To adjust parameters P0–P5:

  • Long press SET for 5 seconds → P0 appears.
  • Press + / – to scroll through parameters.
  • Press SET to enter the parameter → adjust with + / –.
  • Press SET to confirm.
  • Long press SET or wait 10 seconds with no action to save and exit.
P0 – Refrigeration / Heating Mode
  • C = Cooling Mode
    • Relay ON when temperature ≥ Set Point.
    • Relay OFF when temperature ≤ Set Point – P1.
  • H = Heating Mode
    • Relay ON when temperature ≤ Set Point.
    • Relay OFF when temperature ≥ Set Point + P1.
P1 – Return Difference (Hysteresis)
  • Range: 0.1 – 15.0°C
  • Prevents frequent switching by setting a gap between ON/OFF temperatures.

Example – Cooling:

  • Set Point: 25°C, P1: 2°C
  • Relay ON at 25°C, OFF at 23°C → repeats cycle.

Example – Heating:

  • Set Point: 25°C, P1: 2°C
  • Relay ON at 25°C, OFF at 27°C → repeats cycle.
P2 – Maximum Temperature Limit
  • Limits the highest allowed Set Point.
  • Range: up to 110°C.

Example:

If P2 = 60°C, you cannot set the target temperature above 60°C.

P3 – Minimum Temperature Limit
  • Limits the lowest allowed Set Point.
  • Range: down to -50°C.

Example:

If P3 = 2°C, you cannot set the target temperature below 2°C.

P4 – Temperature Calibration
  • Correct sensor deviations.
  • Range: -7.0°C to +7.0°C.

Example:

Display shows 25.0°C:

  • Set P4 = +1.5 → display shows 26.5°C.
  • Set P4 = -1.5 → display shows 23.5°C.
P5 – Delay Start (Minutes)
  • Range: 0–10 minutes.
  • Protects compressor/heater life by delaying restart.

Example – Cooling:

If delay = 5 minutes, after stopping the cooling device, it won’t restart until at least 5 minutes have passed.

P7 – Memory Function
  • Set P7 = ON → Retains last settings after power loss.
5. Restore Factory Settings

If settings are incorrect or unstable:

  1. Power OFF.
  2. Press + and together.
  3. Power ON while holding both buttons.
  4. All settings reset to factory defaults.